Manta Ray Mechanical Soil Anchors
|
Manta Ray and Stingray anchors offer many significant advantages:
|
![]() Sting Ray Anchor |
|
|
There are eight Manta Ray Anchors and three Stingray Anchors with light to heavy duty holding capacities. Shown to the left are six different Manta Ray anchor heads. All anchors are made of galvanized ductile iron, can be driven with the drive steel set (except the MR-88 & M-68) and can be tested to the desired holding capacity with the load locker.
|
||
Manta Ray & Stingray Anchor Structural Properties
Safety Factor 2:1 |
Weight Per Each |
|||
& Diameter** |
Number |
|||
| MR-68 | 2.5 kips (11 kN) |
3/8" - 16 UNC (10 mm) |
B8S-03 | 1 lbs. (0.45 kg) |
| MR-88 | 5 kips (22 kN) |
1/2" - 13 UNC (12 mm) |
B8S-04 | 2.2 lbs. (1 kg) |
(36 kN) |
(20 mm) |
R61-06 | 4.7 lbs. (2.1 kg) |
|
(45 kN) |
(20 mm) |
R61-06 | 6 lbs. (2.7 kg) |
|
|
MR-2
|
(89 kN) |
(20 mm) |
R61-06 | 10 lbs. (4.5 kg) |
|
MR-1
|
(89 kN) |
(20 mm) |
R61-06 | 12 lbs. (5.4 kg) |
|
MR-SR
|
(89 kN) |
(20 mm) |
R61-06 | 21 lbs. (9.5 kg) |
| MK-B | 20 kips (89 kN) |
(20 mm) |
R61-06 | 85 lbs. (38.5) |
| Sting Ray | Safety Factor | Part Number | Working Load | Weight |
| SR-1 | 45.5 kips (198 kN) |
1-1/8" (28 mm) |
R61-09 | 47 lbs. (21.3 kg) |
| SR-2 | 50 kips (223 kN) |
1-1/8" (28 mm) |
R61-09 | 66 lbs. (30 kg) |
| SR-3 | 50 kips (223 kN) |
1-1/8" (28 mm) |
R61-09 | 91 lbs. (41.2) |
|
Williams Anchor Rods are fully threaded and can be field cut and coupled.
**Anchor Rod Lengths: R61-06 & R61-09 up to 50 feet uncoated. B8S-03 & B8S-04 up to 20 feet Recommend: Galvanized rods should be cut to size prior to galvanizing to insure good nut fit. |
||||
Manta Ray Anchor Holding Capacities in Listed Soils
|
Common Soil
Type Description |
Typical
Blow Count "N" Per ASTM-D1586 |
MR-68
|
MR-88
|
MR-4
|
MR-3
|
MR-2
|
MR-1
|
MR-SR
|
MK-B
|
| Peat, Organic Silts; Inundates Silts, Fly Ash |
0 - 5
|
N.A.
|
0.2-0.9 kips
(.9-4 kN) (4,6) |
0.3-1.5 kips
(1.3-7 kN) (4,6) |
0.8-3 kips
(3.5-13 kN) (4,6) |
2-5 kips
(9-22 kN) (4,6) |
3-8 kips
(13-37 kN) (4,6) |
4-12 kips
(18-53 kN) (4,6) |
6-16 kips
(27-71 kN) (4,6) |
| Loose fine Sand; Alluvium; Soft-Firm Clays; Varied Clays; Fills |
4 - 8
|
0.4-.8
(1.8-3.5 kN) (4,6) |
0.9-1.5 kips
(4-7 kN) (4,6) |
1.5-2.5 kips
(7-11 kN) (4,6) |
3-5 kips
(13-22 kN) (4,6) |
5-8 kips
(22-36 kN) (4,6) |
8-12 kips
(36-53 kN) (4,6) |
9-14 kips
(40-62 kN) (4,6) |
13-20 kips
(58-89 kN) (4,6) |
| Loose to Medium Dense Fine to Coarse Sand; Firm to Stiff Clays and Silts |
7 - 14
|
0.75-1.25 kips
(3.5 -6 kN) (4) |
1.5-2.5 kips
(7-11 kN) (4) |
2.5-4 kips
(11-18 kN) (4) |
5-8 kips
(22-36 kN) (4) |
7-10 kips
(31-44 kN) (4) |
10-15 kips
(44-67 kN) (4) |
14-18 kips
(62-80 kN) (4) |
20 kips
(89 kN) (4) |
| Medium Dense Coarse Sand and Sandy Gravel; Stiff to very Stiff Silts and Clays |
14 - 25
|
1-1.5 kips
(5-7 kN) (4) |
2-3 kips
(9-13 kN) (4) |
3.5-4.5 kips
(16-20 kN) (4) |
7-9 kips
(31-40 kN) (4) |
9-12 kips
(40-53 kN) (4) |
15-20 kips
(67-89 kN) (4) |
18-20 kips
(80-89 kN) (4) |
20 kips
(89 kN) (2,4) |
| Medium Dense Sandy Gravel; Very Stiff to Hard Silts and Clays |
24 - 40
|
1.5-2 kips
(7-9 kN) (4) |
3-4 kips
(13-18 kN) (4) |
4.5-6 kips
(20-25 kN) (4) |
9-10 kips
(40-45 kN) (4) |
12-18 kips
(53-80 kN) (4) |
18-20 kips
(80-89 kN) (2,4) |
20 kips
(89 kN) (2,4) |
20 kips
(89 kN) (2,4) |
| Dense Clays, Sands and Gravel; Hard Slits and Clays |
35 - 50
|
2-2.5 kips
(9-11 kN) (4) |
4-5 kips
(18-22 kN) (4) |
6-8.5 kips
(27-36 kN) (4) |
10 kips
(45 kN) (2,4) |
15-20 kips
(67-89 kN) (2,4) |
20 kips
(89 kN) (2,4) |
20 kips
(89 kN) (2,3,4) |
20 kips
(89 kN) (1,3) |
| Dense Fine Sand; Very hard Silts and Clays |
45 - 60
|
2.5 kips
(11 kN) (2,3,4) |
5 kips
(22 kN) (2,3,4) |
8.5 kips
(36 kN) (2,3,4) |
10 kips
(45 kN) (2,3,4) |
20 kips
(89 kN) (2,4) |
20 kips
(89 kN) (1,3,4) |
20 kips
(89 kN) (1,3) |
20 kips
(89 kN) (1,3,5) |
| Very Dense and/or Cemented Sands; Coarse Gravel and Cobbles |
60 - 100+
|
2.5 kips
(1 kN) (1,3) |
5 kips
(22 kN) (1,3) |
8.5 kips
(36 kN) (1,3) |
10 kips
(45 kN) (1,3) |
20 kips
(89 kN) (1,3,4) |
20 kips
(89 kN) (1,3) |
20 kips
(89 kN) (1,3,5) |
20 kips
(89 kN) (1,3,5) |
1 - Drilled hole required to install.
2 - Installation may be difficult. Pilot hole may be required.
3 - Holding capacity limited by working load of anchors
4 - Holding capacity limited by soil failure.
5 - Not recommended in these soils.
6 - Wide variation in soil properties reduces prediction accuracy.
Pre-constructed field test recommended.
Minimum 2:1 Safety Factor Recommended
* Use this chart for estimation only.
* True capacity must be tested with anchor locker.
Stingray Anchor Holding Capacities in Listed Soils
| Common Soil Type Description |
Typical Blow Count "N" Per ASTM-D1586 |
SR-1 | SR-2 | SR-3 |
| Peat, Organic Silts; Inundates Silts, Fly Ash |
0 - 5 | N.A. | N.A. | N.A. |
| Loose fine Sand; Alluvium; Soft-Firm Clays; Varied Clays; Fills |
13-19 kips (58-82 kN) (4,6) |
19-28 kips (85-125 kN) (4,6) |
24-37 kips (107-165 kN) (4,6) |
|
| Loose to Medium Dense Fine to Coarse Sand; Firm to Stiff Clays and Silts |
16-24 kips (72-107 kN) (4) |
27-36 kips (120-160 kN) (4) |
37-48 kips (165-214 kN) (4) |
|
| Medium Dense Coarse Sand and Sandy Gravel; Stiff to very Stiff Silts and Clays |
24-32 kips (107-142 kN) (4) |
31-48 kips (138-214 kN) (4) |
48-50 kips (214-253 kN) (4) |
|
| Medium Dense Sandy Gravel; Very Stiff to Hard Silts and Clays |
29-41 kips (129-182 kN) (4) |
46-50 kips (205-223 kN) (4) |
50 kips (253 kN) (4) |
|
| Dense Clays, Sands and Gravel; Hard Slits and Clays |
39-45.5 kips (173-198 kN) (4) |
50 kips (253 kN) (2,4) |
50 kips (253 kN) (2,3,4) |
|
| Dense Fine Sand; Very hard Silts and Clays |
45.5 kips (198 kN) (2,4) |
50 kips (253 kN) (2,4) |
50 kips (253 kN) (2,3) |
|
| Very Dense and/or Cemented Sands; Coarse Gravel and Cobbles |
45.5 kips (198 kN (1,3) |
50 kips (253 kN) (1,3) |
50 kips (253 kN) (1,3,5) |
1 - Drilled hole required to install.
2 - Installation may be difficult. Pilot hole may be required.
3 - Holding capacity limited by working load of anchors
4 - Holding capacity limited by soil failure.
5 - Not recommended in these soils.
6 - Wide variation in soil properties reduces prediction accuracy.
Pre-constructed field test recommended.
Minimum 2:1 Safety Factor Recommended
* Use this chart for estimation only.
* True capacity must be tested with anchor locker.